UK bathroom lighting zones come from the IET Wiring Regulations, BS 7671, section 701. Zone 0 is the inside of the bath or shower tray. Zone 1 is the space straight above it, to a height of 2.25 m. Zone 2 is a band reaching 0.6 m out from the edge of zone 1, to the same height. Any light in zone 1 or zone 2 must be rated at least IPX4, and its maker must confirm that it suits that zone.

Below, each zone in plain terms, the special case of walk-in showers, where a mirror light can go, and what the Building Regulations say about the work.

The bathroom zones at a glance

The figures come from the SELECT pocket guide to section 701 of BS 7671.

Zone Where it is What a light there needs
Zone 0 Inside the bath or shower tray Fixed, at least IPX7, and run on a safety extra-low voltage (SELV) supply of no more than 12 V AC or 30 V DC, with that supply installed outside the zones
Zone 1 Above the bath or tray, up to 2.25 m from the floor, or to the highest fixed shower head if that is higher. The space under the bath counts too if you can reach it without a tool Fixed, at least IPX4, and suitable for zone 1 according to the maker's instructions
Zone 2 A band 0.6 m wide around zone 1, to the same height At least IPX4, and confirmed by the maker as suitable for the zone
Outside the zones The rest of the room The general wiring rules, with every circuit in the room protected by a 30 mA RCD

What does zone 2 mean in practice?

Take a tape measure to the outside edge of the bath or shower tray and measure 0.6 m out across the floor. Everything in that band, from the floor up to 2.25 m, is zone 2. A wall light on the wall beside the bath, within that 0.6 m, is in zone 2. A light on the wall directly above the bath is in zone 1.

Height matters as much as distance. In many British bathrooms the ceiling is only a little above 2.25 m, so a ceiling light over the bath can sit just above zone 1 on paper. Steam still rises, though, and Electrical Safety First prefers enclosed ceiling lights to ones that hang down. An enclosed fitting rated IPX4 or better is the sensible choice anywhere near the bath or shower.

Walk-in showers and wet rooms

A shower with no tray changes the shape of the zones. Zone 1 then reaches 1.2 m horizontally from the centre point of the fixed shower head, on the wall or ceiling, and there is no zone 2 at all. Zone 0 becomes a layer 10 cm deep across the same area. The height of zone 1 is still 2.25 m, or the highest fixed shower head if that is higher.

In a small wet room with a ceiling-mounted rainfall head, a 1.2 m circle can take in most of the room. Measure it before you choose any light for that space.

What IP rating do bathroom lights need?

An IP rating has two digits. The first is for dust and solid objects, the second for water. An X means that part wasn't rated. IPX4 means protection against splashes from any direction, and IPX7 means the light survives temporary immersion. A light marked IP44 meets the IPX4 water test and also keeps out solid objects over 1 mm. Our guide to IP ratings for lights explains every digit.

The rating is only half the check. In zones 1 and 2, the maker should also say that the light suits the zone. A light that is rated IP44 but sold for a kitchen is not automatically a bathroom light.

Outside the zones, the regulations don't ask for a particular IP rating. A bathroom is still a steamy room, so follow each light's own instructions: a light sold for dry rooms only, as many indoor lights are, doesn't belong in a bathroom at all.

Switches, pull cords and enclosed lights

Water and wet hands are the reason for most bathroom rules. Electrical Safety First gives three pieces of advice for lighting:

  • Enclosed ceiling lights are better than ones that hang down.
  • Any light that isn't enclosed should be out of reach of someone in the bath or shower, or still wet from it.
  • A ceiling pull-cord switch is a better option than an ordinary wall switch.

Sockets follow a rule of their own: no ordinary socket within 2.5 m of the edge of zone 1. Shaver supply units are the exception.

Mirror lights and the basin

The zones are measured from the bath and the shower only. A washbasin doesn't start a zone of its own. What matters is where the basin stands:

  • Basin well away from the bath or shower: a light beside or above the mirror is outside the zones.
  • Basin within 0.6 m of the bath or tray, as in many compact bathrooms: a mirror light there is likely to be in zone 2. It then needs IPX4 and the maker's confirmation that it suits zone 2.

Fowey is a small glass dome for the wall or ceiling, 13.5 cm across, with a 12 W built-in LED that works from an ordinary switch. It is rated IP44, which protects it from splashes. Its page suggests a kitchen or a desk, and it doesn't say that it suits zone 1 or 2. In a bathroom, we therefore suggest it outside the zones only: beside a mirror over a basin that stands well away from the bath or shower, or on the ceiling away from them. Its eleven glass finishes run from ambers and greens to clear, smoke and opal.

Do you need to tell anyone about the work?

All electrical work in a bathroom must meet BS 7671, and so section 701, whoever does it. What differs across the UK is when the work has to be notified.

England. Under Approved Document P (2013 edition), a new circuit, a replacement consumer unit, and any addition or alteration to circuits in the space around a bath or shower are notifiable. That space is the zones described above: up to 2.25 m high, 0.6 m from the bath or tray, or 1.2 m from the shower head where there is no tray. Replacing an existing light fitting is not notifiable anywhere in the home, but the new light must still suit its zone.

Wales. Welsh Government guidance says that replacing a light fitting doesn't need notifying, but adding an extra lighting point does when it is in a bathroom (or a kitchen, or outdoors).

Scotland and Northern Ireland have their own building regulations. In Scotland, swapping a fitting for one of the same general type doesn't need a building warrant, and the work must still meet BS 7671.

Notifiable work goes through an electrician registered with a government-approved scheme, who certifies it for you, or through your building control body before the work starts. Electrical Safety First recommends a registered electrician for electrical installation work in a bathroom. An electrician can do any of this for you if you prefer, and our fitting guide sets out the safety steps for a like-for-like swap. Part P explained covers the rules for the rest of the house.

Measure first: a five-point check

  1. Measure from the outside edge of the bath or tray to where you want the light.
  2. Measure the height of that spot from the floor, and the height of the fixed shower head.
  3. Name the zone: 0, 1, 2, or outside.
  4. Check the light's IP rating, and that its maker confirms the zone.
  5. Decide whether the job is a straight swap or new wiring, and so whether it is notifiable.

Quick questions

Is there still a zone 3?

Older guides mention one. The current guidance on section 701 describes zones 0, 1 and 2 and the area outside the zones, with no zone 3.

Can I hang a pendant in a bathroom?

Electrical Safety First prefers enclosed ceiling lights, and any light that isn't enclosed should be out of reach of someone in the bath or shower or still wet from it. Within the zones, the light also needs IPX4 and its maker's approval for that zone. In practice, a flush or close-fitting enclosed light is the safer choice.

Can I change the bathroom light myself?

Replacing a fitting is not notifiable in England or Wales, so the law doesn't require a professional for a straight swap. Turn the power off at the consumer unit, prove it is off with a two-pole tester, and choose a light that suits its zone. If any of that feels uncertain, a registered electrician can do it for you. Our article on changing a ceiling light lists what to check first.

Zones, IP ratings and every other key number in the house are on one page in our free Room-by-Room Lighting Guide.

Read more

An oxblood-rendered house front with a black panelled front door and a black fluted outdoor wall light lit beside it, a clipped box in a pot, sunlight
Bathrooms & IP

IP Ratings for Lights: IP20, IP44 and IP65 in Plain English

How to read the two digits of an IP rating, where IP20, IP44, IP65 and IP67 lights belong, how to choose between a porch and an open wall, and what the code leaves out.

Read more
An oxblood limewashed sitting room with a stone fireplace flanked by two small domed glass wall lights and green velvet armchairs, sunlight on the wall
Room by Room

How to Light a Dark or North-Facing Room

A north-facing room gets little direct sun in Britain. Here is how to light its walls and ceiling, choose paint and bulbs that work with cool daylight, and use lamps by day.

Read more